Changzhou Kwell Cooling Equipment Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Chen May
  • Company Name : Changzhou Kwell Cooling Equipment Co., Ltd.
  • Tel : 86-519-83666582
  • Fax : 86-519-83665585
  • Address : Jiangsu,Changzhou,Xiejia Team,Changting Village,Changzhou City,Jiangsu Province,P.R.China
  • Country/Region : China
  • Zip : 213145

Cooling Tower Fill

Cooling Tower Fill
Product Detailed
Related Categories:Cooling Tower
1.Good Chemical and Physical Performance 2.Good anti-flaming performance 3.High strength of assembly

1.Good Chemical and Physical Performance2.Good anti-flaming performance3.High strength of assembly

Product Classification

1)."T" type wave fill  

Sheet spacing: 33mm

Weight: 15.4kg/ m3 (after deformed)

Thickness after forming:15mils

Sheet size: 500mm×2400mm/ 500mm×2000mm/ 500mm×1200mm

2)."S" type wave fill

 Sheet Spacing:31mm

Weight: 17.6kg/ m3 (after deformed)

Thickness after forming:15mils

Sheet size: 500mm×1000mm

3)."TS" fill

 Sheet spacing:18.9mm

Weight: 20.776kg/ m3 (after deformed)

Thickness after forming:10mils

Sheet size: 500mm×2400mm/ 500mm×2000mm/ 500mm×1000mm

4)."HS" fill

Sheet spacing:20mm

Weight: 18.83kg/ m3 (after deformed)

Thickness after forming:10mils

Sheet size: 304mm×2400mm/ 304mm×2000mm/ 304mm×1200mm/ 304mm×1000mm 

  

Feature of filling 

The filling has larger specific surface-area after several technological improvement, this prolongs detention time of drip on filling surface, make heat interchange of water and air more adequate, it is proved by testing that: Comparing to fillings which are applied widely in the market, on the precondition of comparative thermal performance, the airflow resistance of this kind of filling diminishes 8~20%It has the good characteristic of hydrophilicity, proof-oil, high-temperature-resistant, it doesn’t occur geometric alteration under condition of 65°C, and it won't crash and crack under condition of -40°C. Its anti-flaming oxygen index is more than 40.According to practically experience of similary project, the filling is bound by special adhesive, ratio of bonding is no less than 95%, intensity of flat crushing ≥3000 N/m2, shear intensity after being bound for 24 hours is more than 3.3Mpa.It has the good characteristic of hydrophilicity, proof-oil, high-temperature- resistant, anti-ageing. The strength of filling block is more than 300Kg/m2.

The most efficient film fill

The film fill is probably the most thermally efficient fill worldwide.It is well adapted to any induced draft or natural draft cooling tower using normal industrial water quality.Sharp horizontal corrugations allow even water redistribution on the sheet and water rotation for good contact with air. The offset flute design allows vertical rotation of air with limited pressure drop.

Cooling Tower Fill



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.